Overview ENERGYA
ENERGYA: Digital On Air Console
Energya is the highest quality digital console that radio stations have waited for. It is simply innovative, flexible, sophisticated and with an enhanced new-styling ideal for a modern broadcast studio.
Energya got all the features you need: 24 input channel, four microphone input, sixteen analog line input, four AES/EBU digital input, two telco interface, digital router and dramatic improvement in audio quality provided by an all-digital signal path. Energya offers you all the functionality expected from this ultimate console like mixing and monitoring facilities, logic controls, TCP/IP connection and serial control.
Everything is included in an amazing price. Energya has a modern low profile design and intuitive control surface that will be immediately familiar to all users. Energya is the ideal solution for the new computer based studios
INPUT
– 4 Mic transformer balanced inputs
– 4 Digital AES/EBU stereo inputs
– 16 Balanced analog stereo inputs
OUTPUT
-PGM Analog (24 Bit D/A) and Digital AES/EBU with SRC
– UTL Analog (24 Bit D/A) and Digital AES/EBU with SRC
– Mono Analog (24 Bit D/A)
– Telco 1 & 2 CleanFeed Analog (24 Bit D/A) and Digital AES/EBU (48 KHz No- Sync)
CHANNEL FUNCTIONS
– Name assignment to each input (4 characters)
– Source Type ( Mic, Line, Digital, Telco)
– Level adjustment
– Phantom Power (for Mic Input only)
– Insert (for Mic Input only)
– Voice Processor (Compressor, Limiter, Expander)
– Busses assignement (PGM-UTL-Telco 1 and 2)
– Mode Selector (Left/Right/Stereo/Mono)
– Pan
– Balance
– Phase Reverse
– Control Room and Studio Mute
– Timer Restart
– Tally 1 and 2 Logic
– Intercom mode
– Start/Stop Control Logic
MONITORING
– Level Control of the Headphones, Control room and Studio
– CUE Speaker Built-in CUE Speaker (with monitor selector)
– Level Meters on 8.4” Color Display
– Built-in H/P Amplifier
MICROPHONE INPUT: | |
Input configuration | transformer balanced |
Source Impedance | 200 Ω |
Input Level Range | Adjustable from -70 ÷ -40 dBu |
Maximum Input Level | -30 dBu |
Phantom Supply | 42 Vdc selectable, with 3k3 c.c. protection |
Connector | XLR-type, Female, EMI suppressed |
MICROPHONE INSERT: | |
Insert Output configuration | Unbalanced |
Insert Output Impedance | 100 Ω |
Insert Output Level | 0 dBu (range ± 12dB) |
Connector | DSUB 9 pole female |
LINE INPUT: |
|
Input configuration | Electronically balanced |
Input Impedance | >10 KΩ (600 Ω wired selectable) |
Input Level | 0 dBu (Adjustable ± 12 dB) |
Headroom | + 8 dBu |
Connector | DSUB 9 pole female |
EXTERNAL INPUT: | |
Input configuration | Electronically balanced |
Input Impedance | >10 KΩ (600 Ω wired selectable) |
Input Level | 0 dBu (Adjustable ± 12 dB) |
Headroom | + 8 dBu |
Connector | DSUB 9 pole female |
ANALOG OUTPUT: | |
Output configuration | Electronically balanced |
Output Impedance | 100 Ω |
Output Level | 0 dBu (Adjustable ± 12 dB) |
Connector | DSUB 15 pole female |
DIGITAL INPUT: | |
Input configuration | Professional Balanced AES EBU standard |
Input Impedance | 110Ω shielded twisted pair |
Input Sample rate | 32, 44.1, 48, 96 KHz (Auto Detect) |
Connector | DSUB 9 pole female |
DIGITAL OUTPUT: | |
Output configuration | Professional Balanced AES EBU standard |
Output Impedance | 110Ω shielded twisted pair |
Output Sample rate | 32, 44.1, 48, 96 KHz Selectable* |
Connector | DSUB 9 pole female |
SYNCRONIZATIONS: | |
Frame | |
Input / Output configuration | Professional Balanced AES EBU standard |
Input / Output Impedance | 110 Ω shielded twisted pair |
Connector | DSUB 9 pole female |
Word Clock | Greater than 600 Ω |
Input / Output configuration | Professional Balanced AES EBU standard |
Input Impedance | 10 KΩ |
Output Impedance | 100 Ω _ |
Connector | BNC ground |
LOGIC INPUT: | |
Configuration | Opto-coupled (with internally 330Ω protection) |
Max Voltage input | 5 Vdc (for 10 mA input) |
Max Reverse Voltage | 5 Vd |
Connector | DSUB 37 pole female |
LOGIC OUTPUT: | |
Configuration | Optic solid state relay |
Max Voltage | 50 Vdc/ac |
Max Current | 100 mA |
Connector | DSUB 37 pole female |
STUDIO I / O: | |
Studio Logic Input | |
Configuration | Opto-coupled (with internally 330 Ω protection) |
Max Voltage input | 5 Vdc (for 10 mA input) |
Max Reverse Voltage | 5 Vdc |
Studio Logic Output | |
Configuration | Optic solid state relay |
Max Voltage | 50 Vdc/ac |
Max Current | 100 mA |
Connector | DSUB 15 pole female |
ROOM I / O: | |
Room Logic Output | |
Configuration | Optic solid state relay |
Max Voltage | 50 Vdc/ac |
Max Current | 100 mA |
Connector | DSUB 9 pole female |
CRT: | |
Configuration Type | VGA 800×600 (V 72 Hz, H 53,3 KHz) |
Connector | High density DSUB 15 pole female |
RS 232: |
|
Configuration | Type RS232 standard DCE |
Connector | DSUB 9 pole female |
LAN: | |
Configuration | Type ETHERNET 10 Base T |
Connector | RJ 45 |
HEAD PHONES: | |
Configuration | Type Stereo unbalanced |
Output Impedance | 50Ω |
Connector | JACK 6 mm |
GENERAL SPECIFICATIONS
FREQUENCY RESPONSE
Microphone Input to program output 20 Hz ÷ 20 KHz ±0.3 dB
Line Input to program output 30 Hz ÷ 20 KHz ±0.3 dB
NOISE
Micro Amplifier -130 dBu RMS equivalent input noise, 200Ω source,
20 KHz bandwidth
Line Amplifier -120 dBu RMS equivalent input noise, 600Ω source,
20 KHz bandwidth
Output Noise with:
one microphone channel ON, fader at 0 dB, input sensitivity at –50 dB
-80 dBu, reference + 6 dB, 200Ω source,
20 KHz bandwidth
Output Noise with:
one line channel ON, fader at 0 dB, input sensitivity at –50 dB
-82 dBu, reference + 6 dB, 200Ω source,
20 KHz bandwidth
Output Noise with:
no input channel ON
-88 dBu, reference + 6 dB, 20 KHz bandwidth
DISTORTION T.H.D.
Microphone Input to program output: Less than 0.055 %
Line Input to program output: Less than 0.022 %
ASSIGNISOLATION
1 KHz better than -120 dB
20 KHz -80 dB
STEREO SEPARATION
1 KHz -85 dB
20 KHz -82 dB
CMRR ( Line Input )
60 Hz -80 dB
1 KHz -80 dB
20 KHz -75 dB
GROUP DELAY
Analog Input to Analog Output 1,75 mSec
Analog Input to Digital Output 3 mSec
Digital Input to Analog Output 2,8 mSec
Digital Input to Digital Output 4 mSec
GENERAL DATA
Power Supply 115 / 230 VAC 50 – 60 Hz
Power Requirement 60 VA
Operating Temperature 0 ÷ 50 °C